{"title":"NG Trade Blu+ HVAC Products","description":"\u003cp data-pm-slice=\"1 1 []\"\u003e\u003cspan\u003eShop Blu+ HVAC products, components, and replacement parts for residential and commercial heating and cooling systems. Our Blu+ collection includes equipment and service parts selected for dependable performance, system compatibility, and professional HVAC applications.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"ng-blu-eco-9k-115v-single-zone-heat-pump","title":"NG BLU+ ECO 9,000 BTU Single-Zone Mini Split Heat Pump - 21.5 SEER2, 115V (OBMH090B \/ IBMH090B)","description":"\u003cp\u003eA complete 9,000 BTU inverter heat pump system that runs on an ordinary 115V circuit, which makes it one of the easiest ways to condition a bedroom, home office, sunroom or garage without adding a 240V branch circuit. The variable-speed compressor modulates from 2,900 to 10,500 BTU\/h, so instead of cycling on and off it settles into a low continuous output that holds temperature closely and keeps the indoor unit down at 18.5 dB(A) on Silent. At 21.5 SEER2 it comfortably clears the federal minimum for ductless equipment.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIBMH090B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOBMH090B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000 BTU\/h (2,900 - 10,500 BTU\/h inverter range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal heating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000 BTU\/h (2,400 - 11,200 BTU\/h inverter range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.5 \/ 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 (Region IV \/ Region V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.1 \/ 7.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 17°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling at 109°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115V \/ 60Hz \/ 1Ph (103.5 - 126.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e720W \/ 7.6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e930W \/ 9.4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor MCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor MCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.0A \/ 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG, 4-conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-454B (A2L), 21.52 oz factory charge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16 oz per ft beyond pre-charged length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in. liquid, 3\/8 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax line length \/ height difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 ft \/ 49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor airflow (Turbo\/Hi\/Mi\/Lo\/Silent)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e312.0 \/ 235.4 \/ 170.7 \/ 135.4 \/ 105.9 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor sound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43.5 \/ 37.0 \/ 33.0 \/ 23.0 \/ 18.5 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor sound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e53.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,294.1 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGMCC rotary, 2,035 \/ 3,255W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28.70 x 7.87 x 11.50 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.12 x 11.93 x 21.85 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight (indoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.30 \/ 23.59 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight (outdoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56.66 \/ 62.17 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor operating range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 - 122°F cooling, 5 - 75°F heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eAbout the BLU+ ECO Series\u003c\/h3\u003e\u003cp\u003eBLU+ ECO systems ship as matched pairs, one indoor head and one outdoor condenser, pre-engineered to work together. They use R-454B, the low-GWP A2L refrigerant replacing R-410A under the AIM Act, and are ETL listed to UL 1995 and CSA C22.2 No. 236 and AHRI certified. WiFi control is built in.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45794211135597,"sku":"OBMH090B\/IBMH090B","price":956.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-blu-system-head-condenser-remote_bda55973-11d2-4d3c-aa59-912a40c45de5.png?v=1788797750"},{"product_id":"ng-blu-eco-12k-115v-single-zone-heat-pump","title":"NG BLU+ ECO 12,000 BTU Single-Zone Mini Split Heat Pump - 21.3 SEER2, 115V (OBMH120B \/ IBMH120B)","description":"\u003cp\u003eA full ton of inverter-driven cooling and heating on a 115V circuit. This is the largest capacity NG offers at 115V, and it is the usual pick for a converted garage, a large primary bedroom, a bonus room over a garage, or an addition where running a new 240V feeder would be the expensive part of the job. Note the trade-off that comes with 115V at this size: outdoor MCA is 19.0A, so it needs a dedicated 20A circuit with essentially nothing else on it.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIBMH120B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOBMH120B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU\/h (3,800 - 12,600 BTU\/h inverter range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal heating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU\/h (2,730 - 12,500 BTU\/h inverter range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.3 \/ 10.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 (Region IV \/ Region V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.7 \/ 6.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 17°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8,100 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling at 109°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,300 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115V \/ 60Hz \/ 1Ph (103.5 - 126.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,200W \/ 12.3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,116W \/ 11.4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor MCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor MCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.0A \/ 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG, 4-conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-454B (A2L), 24.34 oz factory charge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16 oz per ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in. liquid, 3\/8 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax line length \/ height difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 ft \/ 49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor airflow (Turbo\/Hi\/Mi\/Lo\/Silent)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e353.2 \/ 294.3 \/ 235.4 \/ 176.6 \/ 129.5 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor sound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45.0 \/ 41.0 \/ 37.0 \/ 27.5 \/ 18.5 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor sound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,235.3 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGMCC rotary, 1,930 \/ 3,100W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.57 x 7.87 x 11.61 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.12 x 11.93 x 21.85 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight (indoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.40 \/ 25.57 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight (outdoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e61.29 \/ 67.02 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor operating range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 - 122°F cooling, 5 - 75°F heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eAbout the BLU+ ECO Series\u003c\/h3\u003e\u003cp\u003eBLU+ ECO systems ship as matched pairs, one indoor head and one outdoor condenser, pre-engineered to work together. They use R-454B, the low-GWP A2L refrigerant replacing R-410A under the AIM Act, and are ETL listed to UL 1995 and CSA C22.2 No. 236 and AHRI certified. WiFi control is built in.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45794212937837,"sku":"OBMH120B\/IBMH120B","price":982.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-blu-system-head-condenser-remote_639acb91-b204-4fee-b9bc-82227e9e9085.png?v=1788797760"},{"product_id":"ng-blu-eco-12k-230v-single-zone-heat-pump","title":"NG BLU+ ECO 12,000 BTU Single-Zone Mini Split Heat Pump - 21.3 SEER2, 208\/230V (OBMH121B \/ IBMH121B)","description":"\u003cp\u003eThe 208\/230V version of the 12,000 BTU BLU+ ECO system, and the better choice whenever a 240V circuit is available. Same nominal capacity as the 115V model but it draws only 4.9A in cooling instead of 12.3A, needs just a 15A breaker, and delivers more low-temperature heat: 9,200 BTU\/h at 17°F versus 8,100. The inverter range is also wider on both ends, so it turns down further for shoulder-season loads and reaches higher when it has to recover a space.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIBMH121B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOBMH121B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU\/h (2,700 - 13,800 BTU\/h inverter range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal heating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU\/h (4,200 - 14,100 BTU\/h inverter range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.3 \/ 10.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 (Region IV \/ Region V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.2 \/ 7.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 17°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,200 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling at 109°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230V \/ 60Hz \/ 1Ph (187 - 253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,111W \/ 4.9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,053W \/ 4.7A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor MCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor MCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.0A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG, 4-conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-454B (A2L), 24.69 oz factory charge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16 oz per ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in. liquid, 3\/8 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax line length \/ height difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 ft \/ 49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor airflow (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e347.3 \/ 294.3 \/ 194.2 \/ 153.0 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor sound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e46 \/ 41 \/ 35 \/ 24 \/ 18.5 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor sound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e53.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,235.3 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGMCC rotary, 1,930 \/ 3,100W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.57 x 7.87 x 11.61 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.12 x 11.93 x 21.85 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight (indoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.96 \/ 25.13 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight (outdoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e59.08 \/ 64.37 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor operating range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 - 122°F cooling, 5 - 75°F heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eAbout the BLU+ ECO Series\u003c\/h3\u003e\u003cp\u003eBLU+ ECO systems ship as matched pairs, one indoor head and one outdoor condenser, pre-engineered to work together. They use R-454B, the low-GWP A2L refrigerant replacing R-410A under the AIM Act, and are ETL listed to UL 1995 and CSA C22.2 No. 236 and AHRI certified. WiFi control is built in.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45794213003373,"sku":"OBMH121B\/IBMH121B","price":982.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-blu-system-head-condenser-remote_a554f5f6-3b72-4105-9be2-3f2fcdf21099.png?v=1788797771"},{"product_id":"ng-blu-eco-18k-230v-single-zone-heat-pump","title":"NG BLU+ ECO 18,000 BTU Single-Zone Mini Split Heat Pump - 20.2 SEER2, 208\/230V (OBMH181B \/ IBMH181B)","description":"\u003cp\u003eAn inverter heat pump sized for open-plan living areas, finished basements, large studios and small commercial suites of roughly 700 to 1,000 square feet, depending on envelope and climate. Heating capacity is rated slightly above cooling at 18,800 BTU\/h, and the modulation range starts as low as 2,600 BTU\/h, which is what lets a single head serve a big room without the temperature swing you get from a fixed-speed system. Line set steps up to a 1\/2 in. gas line and the run limit grows to 98.4 ft.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIBMH181B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOBMH181B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18,000 BTU\/h (2,600 - 18,600 BTU\/h inverter range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal heating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18,800 BTU\/h (6,100 - 19,200 BTU\/h inverter range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.2 \/ 11.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 (Region IV \/ Region V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.1 \/ 7.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 17°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13,300 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling at 109°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14,700 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230V \/ 60Hz \/ 1Ph (187 - 253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,565W \/ 7.0A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,790W \/ 8.0A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor MCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor MCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.0A \/ 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG, 4-conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-454B (A2L), 40.57 oz factory charge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16 oz per ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in. liquid, 1\/2 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax line length \/ height difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98.4 ft \/ 65.6 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor airflow (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e470.9 \/ 400.2 \/ 329.6 \/ 270.8 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor sound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.0 \/ 45 \/ 38 \/ 23 \/ 19 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor sound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e58.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,235.3 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGMCC rotary, 4,385W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38.23 x 8.98 x 12.64 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.69 x 12.99 x 21.81 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight (indoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.35 \/ 32.85 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight (outdoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72.31 \/ 78.48 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor operating range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 - 122°F cooling, 5 - 75°F heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eAbout the BLU+ ECO Series\u003c\/h3\u003e\u003cp\u003eBLU+ ECO systems ship as matched pairs, one indoor head and one outdoor condenser, pre-engineered to work together. They use R-454B, the low-GWP A2L refrigerant replacing R-410A under the AIM Act, and are ETL listed to UL 1995 and CSA C22.2 No. 236 and AHRI certified. WiFi control is built in.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45794213068909,"sku":"OBMH181B\/IBMH181B","price":1297.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-blu-system-head-condenser-remote_87c12598-1192-406c-8d48-e10c8d40dfdd.png?v=1788797778"},{"product_id":"ng-blu-eco-24k-230v-single-zone-heat-pump","title":"NG BLU+ ECO 24,000 BTU Single-Zone Mini Split Heat Pump - 18.5 SEER2, 208\/230V (OBMH241B \/ IBMH241B)","description":"\u003cp\u003eTwo tons from a single wall-mounted head, aimed at great rooms, workshops, church halls and light commercial spaces where a duct system is not practical. The heating side is the interesting part: 25,000 BTU\/h nominal, and the low-temperature ratings hold up unusually well, with 22,000 BTU\/h still available at 5°F. Line set capacity doubles to 164 ft with an 82 ft height difference, which gives real freedom in where the condenser lands relative to the head.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIBMH241B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOBMH241B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,000 BTU\/h (6,200 - 24,700 BTU\/h inverter range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal heating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25,000 BTU\/h (11,900 - 27,200 BTU\/h inverter range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.5 \/ 9.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 (Region IV \/ Region V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.0 \/ 7.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 17°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20,200 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling at 109°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230V \/ 60Hz \/ 1Ph (187 - 253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,474W \/ 11.1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,275W \/ 9.9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor MCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor MCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.0A \/ 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG, 4-conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-454B (A2L), 53.62 oz factory charge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32 oz per ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8 in. liquid, 5\/8 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax line length \/ height difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e164 ft \/ 82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor airflow (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e729.9 \/ 547.4 \/ 400.2 \/ 329.6 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor sound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54.0 \/ 46 \/ 41.0 \/ 28 \/ 22 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor sound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,764.7 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGMCC rotary, 4,780 \/ 7,600W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.60 x 9.21 x 13.27 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35.04 x 13.46 x 26.50 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight (indoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.64 \/ 39.68 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight (outdoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e94.58 \/ 102.29 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor operating range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 - 122°F cooling, 5 - 75°F heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eAbout the BLU+ ECO Series\u003c\/h3\u003e\u003cp\u003eBLU+ ECO systems ship as matched pairs, one indoor head and one outdoor condenser, pre-engineered to work together. They use R-454B, the low-GWP A2L refrigerant replacing R-410A under the AIM Act, and are ETL listed to UL 1995 and CSA C22.2 No. 236 and AHRI certified. WiFi control is built in.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45794213134445,"sku":"OBMH241B\/IBMH241B","price":1543.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-blu-system-head-condenser-remote_37bcad57-2777-4d71-a53f-a2fc0b7336ce.png?v=1788797788"},{"product_id":"ng-blu-eco-36k-230v-single-zone-heat-pump","title":"NG BLU+ ECO 36,000 BTU Single-Zone Mini Split Heat Pump - 19.5 SEER2, 208\/230V (OBMH361B \/ IBMH361B)","description":"\u003cp\u003eThe largest single-zone system in the BLU+ ECO line, at three tons from one head. This is the only single-zone ECO model rated down to -13°F outdoor for heating rather than 5°F, so it is the one to specify in a cold climate. Heating modulation reaches 44,000 BTU\/h at the top of its range for fast recovery, and the 213 ft maximum line length is long enough to put the condenser well away from the occupied space. Plan on a 35A circuit and a two-person lift for the 160 lb outdoor section.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIBMH361B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOBMH361B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36,000 BTU\/h (6,600 - 36,800 BTU\/h inverter range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal heating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36,000 BTU\/h (11,400 - 44,000 BTU\/h inverter range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.5 \/ 9.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 (Region IV \/ Region V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.1 \/ 7.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 17°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling at 109°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25,700 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230V \/ 60Hz \/ 1Ph (187 - 253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,830W \/ 17.0A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,580W \/ 16.0A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor MCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor MCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33.0A \/ 35A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG, 4-conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-454B (A2L), 112.88 oz factory charge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32 oz per ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8 in. liquid, 5\/8 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax line length \/ height difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e213.2 ft \/ 98.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor airflow (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e871.1 \/ 676.9 \/ 447.3 \/ 329.6 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor sound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e57.0 \/ 51.0 \/ 45.0 \/ 33.5 \/ 27.5 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor sound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,235.3 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGMCC rotary, 8,095W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.57 x 11.14 x 14.25 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.24 x 16.14 x 31.89 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight (indoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43.43 \/ 56.88 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight (outdoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150.35 \/ 160.27 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor operating range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13 - 122°F cooling, -13 - 75°F heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eAbout the BLU+ ECO Series\u003c\/h3\u003e\u003cp\u003eBLU+ ECO systems ship as matched pairs, one indoor head and one outdoor condenser, pre-engineered to work together. They use R-454B, the low-GWP A2L refrigerant replacing R-410A under the AIM Act, and are ETL listed to UL 1995 and CSA C22.2 No. 236 and AHRI certified. WiFi control is built in.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45794213199981,"sku":"OBMH361B\/IBMH361B","price":2181.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-blu-system-head-condenser-remote_89da6f31-8e30-47a1-9b61-26bfab0d32dc.png?v=1788797795"},{"product_id":"ng-blu-star-12k-115v-single-zone-heat-pump","title":"NG BLU+ STAR 12,000 BTU Single-Zone Cold Climate Heat Pump - 23.2 SEER2, 115V (OMSTAR120E \/ IMSTAR120E)","description":"\u003cp\u003eBLU+ STAR is the ENERGY STAR-qualified tier above the ECO line, and the practical difference is cold weather. Every STAR model is rated to operate down to -13°F outdoor in heating, where the equivalent ECO units stop at 5°F, and this one still produces 3,500 BTU\/h at -13°F. It also runs quieter indoors at 17.5 dB(A) on Silent. All of that on a 115V circuit, which makes it a strong candidate for a bedroom or office in a northern climate where no 240V circuit is available. ENERGY STAR listing matters for utility rebates and for the 25C federal tax credit, both of which usually require it.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIMSTAR120E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOMSTAR120E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU\/h (2,600 - 13,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal heating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU\/h (4,500 - 12,800 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23.2 \/ 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 (Region IV \/ Region V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.4 \/ 7.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating H32 rated \/ COP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8,800 BTU\/h \/ 2.78\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating H42 rated \/ COP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7,300 BTU\/h \/ 2.20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 17°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8,900 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7,300 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -4°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5,100 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -13°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling at 109°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,800 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115V \/ 60Hz \/ 1Ph (103.5 - 126.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e960W \/ 10.0A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e950W \/ 10.3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor MCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor MCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.0A \/ 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-454B (A2L), 33.51 oz factory charge; 0.16 oz\/ft additional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in. liquid, 3\/8 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax line length \/ height difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 ft \/ 49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor airflow (Turbo\/Hi\/Mi\/Lo\/Silent)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e370.8 \/ 306.1 \/ 235.4 \/ 188.4 \/ 141.3 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor sound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e44.0 \/ 40.5 \/ 35.0 \/ 26.5 \/ 17.5 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor sound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e53.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGMCC rotary, 2,035 \/ 3,255W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.57 x 7.87 x 11.61 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.12 x 11.93 x 21.85 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight (indoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.84 \/ 26.01 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight (outdoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64.59 \/ 70.11 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor operating range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13 - 122°F cooling, -13 - 75°F heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eAbout the BLU+ STAR Series\u003c\/h3\u003e\u003cp\u003eBLU+ STAR is the ENERGY STAR-qualified tier of the R-454B lineup. Every model in the series operates down to -13°F outdoor ambient in heating mode and publishes full low-temperature capacity tables at 17°F, 5°F, -4°F and -13°F, which is what utility and tax incentive programs generally ask for. ETL listed to UL 1995 and CSA C22.2 No. 236, AHRI certified, WiFi enabled.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45794213232749,"sku":"OMSTAR120E\/IMSTAR120E","price":1415.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-blu-star-wall-head_c6363a11-6ba3-4ff8-b7e4-be9ccf32bf2d.png?v=1788797805"},{"product_id":"ng-blu-star-12k-230v-single-zone-heat-pump","title":"NG BLU+ STAR 12,000 BTU Single-Zone Cold Climate Heat Pump - 23.1 SEER2, 208\/230V (OMSTAR121E \/ IMSTAR121E)","description":"\u003cp\u003eThe 240V version of the STAR 12K, and the stronger performer of the two: HSPF2 rises from 10.4 to 11.5, and low-temperature heating improves across the board, with 5,300 BTU\/h at -13°F against 3,500 for the 115V model. Cooling current drops to 4.5A so it runs on a 15A circuit. If a 240V circuit is available or easy to add, this is the version to specify. ENERGY STAR qualified.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIMSTAR121E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOMSTAR121E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU\/h (2,600 - 13,700 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal heating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU\/h (4,100 - 14,400 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23.1 \/ 12.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 (Region IV \/ Region V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11.5 \/ 8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating H32 rated \/ COP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,600 BTU\/h \/ 2.84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating H42 rated \/ COP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8,600 BTU\/h \/ 2.35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 17°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,900 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -4°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6,700 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -13°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5,300 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling at 109°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7,900 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,700 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230V \/ 60Hz \/ 1Ph (187 - 253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e984W \/ 4.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e953W \/ 4.3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor MCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor MCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.0A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-454B (A2L), 32.45 oz factory charge; 0.16 oz\/ft additional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in. liquid, 3\/8 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax line length \/ height difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 ft \/ 49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor airflow (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e382.6 \/ 294.3 \/ 194.2 \/ 153.0 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor sound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e46 \/ 43 \/ 37 \/ 20 \/ 19 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor sound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGMCC rotary, 2,035 \/ 3,255W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.57 x 7.87 x 11.61 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.12 x 11.93 x 21.85 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight (indoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.96 \/ 24.25 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight (outdoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62.17 \/ 67.68 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor operating range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13 - 122°F cooling, -13 - 75°F heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eAbout the BLU+ STAR Series\u003c\/h3\u003e\u003cp\u003eBLU+ STAR is the ENERGY STAR-qualified tier of the R-454B lineup. Every model in the series operates down to -13°F outdoor ambient in heating mode and publishes full low-temperature capacity tables at 17°F, 5°F, -4°F and -13°F, which is what utility and tax incentive programs generally ask for. ETL listed to UL 1995 and CSA C22.2 No. 236, AHRI certified, WiFi enabled.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45794213331053,"sku":"OMSTAR121E\/IMSTAR121E","price":1531.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-blu-star-wall-head_6033f0ef-8657-46ee-a9d1-1c7328dbfbc1.png?v=1788797813"},{"product_id":"ng-blu-star-18k-230v-single-zone-heat-pump","title":"NG BLU+ STAR 18,000 BTU Single-Zone Cold Climate Heat Pump - 24.0 SEER2, 208\/230V (OMSTAR181E \/ IMSTAR181E)","description":"\u003cp\u003eAt 24.0 SEER2 this is the most efficient single-zone system NG publishes, and it holds 14,500 BTU\/h at 17°F, roughly 80 percent of nominal heating capacity, which is the number to look at when sizing for a cold-climate design day. Sized for open living areas and finished basements in the 700 to 1,000 square foot range. ENERGY STAR qualified, so it should be checked against local utility rebate lists and the 25C credit before the customer buys.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIMSTAR181E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOMSTAR181E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18,000 BTU\/h (3,600 - 20,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal heating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18,000 BTU\/h (7,600 - 22,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24.0 \/ 13.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 (Region IV \/ Region V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11.1 \/ 8.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating H32 rated \/ COP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13,000 BTU\/h \/ 2.60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating H42 rated \/ COP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13,000 BTU\/h \/ 2.35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 17°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -4°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,700 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -13°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7,900 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling at 109°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230V \/ 60Hz \/ 1Ph (187 - 253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,333W \/ 6.0A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,385W \/ 6.2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor MCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor MCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.0A \/ 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-454B (A2L), 47.97 oz factory charge; 0.16 oz\/ft additional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in. liquid, 1\/2 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax line length \/ height difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98.4 ft \/ 65.6 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor airflow (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e759.3 \/ 500.3 \/ 441.4 \/ 370.8 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor sound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54 \/ 45 \/ 40.0 \/ 26 \/ 20 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor sound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e59.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGMCC rotary, 4,315W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.60 x 9.21 x 13.27 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35.04 x 13.46 x 26.50 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight (indoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.42 \/ 39.68 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight (outdoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e92.59 \/ 100.31 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor operating range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13 - 122°F cooling, -13 - 75°F heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eAbout the BLU+ STAR Series\u003c\/h3\u003e\u003cp\u003eBLU+ STAR is the ENERGY STAR-qualified tier of the R-454B lineup. Every model in the series operates down to -13°F outdoor ambient in heating mode and publishes full low-temperature capacity tables at 17°F, 5°F, -4°F and -13°F, which is what utility and tax incentive programs generally ask for. ETL listed to UL 1995 and CSA C22.2 No. 236, AHRI certified, WiFi enabled.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45794213396589,"sku":"OMSTAR181E\/IMSTAR181E","price":1889.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-blu-star-wall-head_481f7904-cda0-45fe-9830-7e4d511baad9.png?v=1788797822"},{"product_id":"ng-blu-star-24k-230v-single-zone-heat-pump","title":"NG BLU+ STAR 24,000 BTU Single-Zone Cold Climate Heat Pump - 23.5 SEER2, 208\/230V (OMSTAR241E \/ IMSTAR241E)","description":"\u003cp\u003eThe largest system in the BLU+ STAR line: two tons of cooling, 25,000 BTU\/h of heating, and 21,300 BTU\/h still delivered at 17°F. Cold-climate heating capacity is the reason to pay the premium over the equivalent ECO 24K, which stops at 5°F ambient. The 164 ft line set allowance gives real placement flexibility on retrofits where the only good condenser location is around a corner or up a level. ENERGY STAR qualified.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIMSTAR241E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOMSTAR241E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,000 BTU\/h (9,700 - 27,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal heating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25,000 BTU\/h (11,300 - 32,700 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23.5 \/ 13.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 (Region IV \/ Region V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.0 \/ 7.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating H32 rated \/ COP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19,500 BTU\/h \/ 2.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating H42 rated \/ COP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17,800 BTU\/h \/ 2.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 17°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21,300 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17,800 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -4°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,300 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -13°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling at 109°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20,700 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230V \/ 60Hz \/ 1Ph (187 - 253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,846W \/ 8.0A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,379W \/ 10.4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor MCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor MCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24.0A \/ 25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-454B (A2L), 70.55 oz factory charge; 0.32 oz\/ft additional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8 in. liquid, 5\/8 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax line length \/ height difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e164 ft \/ 82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor airflow (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e759.3 \/ 588.6 \/ 459.1 \/ 382.6 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor sound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54.0 \/ 48.5 \/ 43.5 \/ 27.5 \/ 20.5 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor sound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGMCC rotary, 4,780 \/ 7,600W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.60 x 9.21 x 13.27 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38.24 x 16.14 x 31.79 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight (indoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.86 \/ 40.56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight (outdoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e122.13 \/ 132.28 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor operating range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13 - 122°F cooling, -13 - 75°F heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eAbout the BLU+ STAR Series\u003c\/h3\u003e\u003cp\u003eBLU+ STAR is the ENERGY STAR-qualified tier of the R-454B lineup. Every model in the series operates down to -13°F outdoor ambient in heating mode and publishes full low-temperature capacity tables at 17°F, 5°F, -4°F and -13°F, which is what utility and tax incentive programs generally ask for. ETL listed to UL 1995 and CSA C22.2 No. 236, AHRI certified, WiFi enabled.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45794213429357,"sku":"OMSTAR241E\/IMSTAR241E","price":2356.39,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-blu-star-wall-head_6049cfe9-e985-44a0-991c-2db1570d4542.png?v=1788797828"},{"product_id":"ng-blu-multi-zone-18k-condenser-3-zone","title":"NG BLU+ Multi-Zone 18,000 BTU Inverter Condenser - 3 Zone, 23 SEER2, R-454B (MOBMH180D)","description":"\u003cp\u003eThe entry point into the BLU+ multi-zone platform: one condenser feeding up to three indoor units, each with its own thermostat and its own schedule. An EXV at every port meters refrigerant per zone, so a bedroom calling for a small amount of cooling does not force the compressor to run at the rate the living room wants. Low-ambient heating is genuinely usable, with 8,000 BTU\/h still on tap at -13°F. Indoor units are sold separately, which is what lets you mix wall-mounted heads and cassettes on one system.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZones supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 3 indoor units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18,000 BTU\/h (5,400 - 21,600 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal heating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19,000 BTU\/h (5,700 - 21,600 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 \/ 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 (Region IV \/ Region V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 \/ 7.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 17°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -4°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -13°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling at 109°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230V \/ 60Hz \/ 1Ph (187 - 253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,440W \/ 6.2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,465W \/ 6.6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16A \/ 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAWG 14-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-454B (A2L), 61.73 oz factory charge; 0.16 oz\/ft additional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMetering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEXV plus capillary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePort connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 x 1\/4 in. liquid, 3 x 3\/8 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax line length per indoor unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal system line length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e196.8 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,765.8 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGMCC twin-rotary, 4,730W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35.04 x 13.46 x 26.50 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100.53 \/ 109.35 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13 - 122°F cooling, -13 - 75°F heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eBuilding the system\u003c\/h3\u003e\u003cp\u003eIndoor units are ordered separately so the head schedule can be matched to the actual room-by-room load calculation. Wall-mount heads (MIBMHW60D through MIBMHW24D) and 4-way cassettes (MIBMHC90D through MIBMHC18D) can be mixed on the same condenser. Cassettes also require decorative panel PAMIC918D.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804162318445,"sku":"MOBMH180D","price":1802.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-multi-zone-wall-cassette-condenser_3a35b278-b4ab-4b20-92ce-ba7f0b726ab8.png?v=1788874709"},{"product_id":"ng-blu-multi-zone-27k-condenser-4-zone","title":"NG BLU+ Multi-Zone 26,000 BTU Inverter Condenser - 4 Zone, 23 SEER2, R-454B (MOBMH270D)","description":"\u003cp\u003eA four-port condenser rated 26,000 BTU\/h cooling and 27,000 BTU\/h heating, sized for a typical three or four bedroom retrofit. Because multi-zone systems are diversified rather than additive, the connected indoor capacity can exceed the outdoor rating: the four heads will rarely all call at full output simultaneously. One of the four gas ports is 1\/2 in. rather than 3\/8 in., which is where the largest head on the system belongs. Total allowable pipe run is 262.4 ft across the system with up to 114.8 ft to any single head.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZones supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 4 indoor units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26,000 BTU\/h (7,200 - 32,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal heating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27,000 BTU\/h (8,400 - 29,200 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 \/ 12.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 (Region IV \/ Region V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.5 \/ 7.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 17°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -4°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -13°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11,800 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling at 109°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,800 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230V \/ 60Hz \/ 1Ph (187 - 253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,130W \/ 10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,198W \/ 10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23A \/ 25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAWG 14-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-454B (A2L), 84.66 oz factory charge; 0.16 oz\/ft additional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMetering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEXV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePort connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 x 1\/4 in. liquid; 3 x 3\/8 in. + 1 x 1\/2 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax line length per indoor unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e114.8 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal system line length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e262.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,130.7 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e61 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGMCC rotary, 4,780 \/ 7,600W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.24 x 16.14 x 31.89 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e138.89 \/ 149.69 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13 - 122°F cooling, -13 - 75°F heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eBuilding the system\u003c\/h3\u003e\u003cp\u003eIndoor units are ordered separately so the head schedule can be matched to the actual room-by-room load calculation. Wall-mount heads (MIBMHW60D through MIBMHW24D) and 4-way cassettes (MIBMHC90D through MIBMHC18D) can be mixed on the same condenser. Cassettes also require decorative panel PAMIC918D.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804162941037,"sku":"MOBMH270D","price":2436.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-multi-zone-wall-cassette-condenser_3e5dcc32-0f61-4526-ba84-737f52fc2384.png?v=1788874719"},{"product_id":"ng-blu-multi-zone-36k-condenser-5-zone","title":"NG BLU+ Multi-Zone 35,000 BTU Inverter Condenser - 5 Zone, 23.1 SEER2, R-454B (MOBMH360D)","description":"\u003cp\u003eFive zones from one condenser, and the strongest cold-weather performer in the BLU+ multi-zone range on a percentage basis: 31,600 BTU\/h at 17°F against a 37,000 BTU\/h nominal rating, and 20,000 BTU\/h still available at -13°F. That profile suits a whole-house ductless retrofit in a northern climate where the design day matters more than the nameplate. Same cabinet as the 27K, so the pad, clearances and mounting hardware carry over.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZones supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 5 indoor units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35,000 BTU\/h (9,000 - 40,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal heating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37,000 BTU\/h (10,000 - 40,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23.1 \/ 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 (Region IV \/ Region V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 \/ 7.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 17°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -4°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -13°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling at 109°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230V \/ 60Hz \/ 1Ph (187 - 253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,915W \/ 13A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,098W \/ 14A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.5A \/ 35A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAWG 14-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-454B (A2L), 120.63 oz factory charge; 0.16 oz\/ft additional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMetering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEXV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePort connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 x 1\/4 in. liquid; 4 x 3\/8 in. + 1 x 1\/2 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax line length per indoor unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e114.8 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal system line length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e262.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,148.4 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGMCC rotary, 10,010W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.24 x 16.14 x 31.89 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e168.87 \/ 180.12 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13 - 122°F cooling, -13 - 75°F heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eBuilding the system\u003c\/h3\u003e\u003cp\u003eIndoor units are ordered separately so the head schedule can be matched to the actual room-by-room load calculation. Wall-mount heads (MIBMHW60D through MIBMHW24D) and 4-way cassettes (MIBMHC90D through MIBMHC18D) can be mixed on the same condenser. Cassettes also require decorative panel PAMIC918D.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804163235949,"sku":"MOBMH360D","price":3128.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-multi-zone-wall-cassette-condenser_7612d20b-6652-490e-966c-b5fd457a83a5.png?v=1788874726"},{"product_id":"ng-blu-multi-zone-48k-condenser-6-zone","title":"NG BLU+ Multi-Zone 45,000 BTU Inverter Condenser - 6 Zone, 21.3 SEER2, R-454B (MOBMH480D)","description":"\u003cp\u003eThe flagship multi-zone condenser: six ports, 45,000 BTU\/h cooling and 48,000 BTU\/h heating, in a tall twin-fan cabinet at 52.5 in. high. Two of the six gas ports are 1\/2 in., so the system can carry two large heads plus four smaller ones. This is whole-house or small-commercial equipment; at 254 lb shipping it needs a proper pad or stand, mechanical assistance to set, and a 40A circuit. Check the connected-capacity limits before committing to a head schedule.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZones supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 6 indoor units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45,000 BTU\/h (12,000 - 49,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal heating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (13,000 - 55,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.3 \/ 11.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 (Region IV \/ Region V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 \/ 7.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 17°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -4°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -13°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling at 109°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230V \/ 60Hz \/ 1Ph (187 - 253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,850W \/ 17.3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,908W \/ 17.3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAWG 14-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-454B (A2L), 148.15 oz factory charge; 0.16 oz\/ft additional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMetering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEXV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePort connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 x 1\/4 in. liquid; 4 x 3\/8 in. + 2 x 1\/2 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax line length per indoor unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e114.8 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal system line length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e262.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4,502.8 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGMCC rotary, 13,700W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.48 x 16.34 x 52.48 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e222.00 \/ 254.19 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13 - 122°F cooling, -13 - 75°F heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eBuilding the system\u003c\/h3\u003e\u003cp\u003eIndoor units are ordered separately so the head schedule can be matched to the actual room-by-room load calculation. Wall-mount heads (MIBMHW60D through MIBMHW24D) and 4-way cassettes (MIBMHC90D through MIBMHC18D) can be mixed on the same condenser. Cassettes also require decorative panel PAMIC918D.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804163596397,"sku":"MOBMH480D","price":4164.42,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-multi-zone-wall-cassette-condenser_4817dc3e-4fa9-4804-8759-70fe2e03a2f3.png?v=1788874733"},{"product_id":"ng-blu-multi-zone-6k-wall-mount-air-handler","title":"NG BLU+ Multi-Zone 6,000 BTU Wall-Mount Air Handler (MIBMHW60D)","description":"\u003cp\u003eThe smallest wall-mounted head in the BLU+ multi-zone range, intended for the rooms that a 9,000 BTU head would badly oversize: a small bedroom, a nursery, a home office, a bathroom or a walk-in closet. Oversizing a zone is the most common cause of poor humidity control in a ductless retrofit, and a 6K head is often the right answer where the load calculation lands under about 7,000 BTU\/h. Pairs with any BLU+ multi-zone condenser.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-454B (A2L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible outdoor units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMOBMH180D, MOBMH270D, MOBMH360D, MOBMH480D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eMulti-zone component, sold separately\u003c\/h3\u003e\u003cp\u003eThis is an indoor component of a BLU+ multi-zone system and does not operate on its own. It must be paired with a BLU+ multi-zone condenser (MOBMH180D, MOBMH270D, MOBMH360D or MOBMH480D). Confirm total connected capacity and port sizing against the condenser before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804163891309,"sku":"MIBMHW60D","price":464.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-wall-head-front_53082e01-5167-4771-bb82-0f348d682bbc.png?v=1788874740"},{"product_id":"ng-blu-multi-zone-9k-wall-mount-air-handler","title":"NG BLU+ Multi-Zone 9,000 BTU Wall-Mount Air Handler - 24.6 SEER2 (MIBMHW90D)","description":"\u003cp\u003eThe most efficient head in the BLU+ multi-zone lineup at 24.6 SEER2, and the workhorse size for bedrooms and offices of roughly 300 to 450 square feet. It drops to 19.5 dB(A) on the lowest fan speed, which is quiet enough to sleep beside, and it turns down to 3,100 BTU\/h so it can hold a small room without short cycling. Requires a BLU+ multi-zone condenser; it is not a standalone system.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000 BTU\/h (3,100 - 10,900 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal heating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000 BTU\/h (4,200 - 14,200 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24.6 \/ 14.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 (Region IV \/ Region V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.0 \/ 9.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 17°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,200 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8,200 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -4°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -13°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMoisture removal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 L\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e382.6 \/ 294.3 \/ 194.2 \/ 153.0 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45.5 \/ 42 \/ 36 \/ 21 \/ 19.5 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230V \/ 60Hz \/ 1Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan motor RLA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMetering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEXV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in. liquid, 3\/8 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax line length \/ height difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 ft \/ 49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.57 x 7.87 x 11.61 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.96 \/ 24.25 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor operating range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 - 90°F cooling, 32 - 86°F heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eMulti-zone component, sold separately\u003c\/h3\u003e\u003cp\u003eThis is an indoor component of a BLU+ multi-zone system and does not operate on its own. It must be paired with a BLU+ multi-zone condenser (MOBMH180D, MOBMH270D, MOBMH360D or MOBMH480D). Confirm total connected capacity and port sizing against the condenser before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804164186221,"sku":"MIBMHW90D","price":482.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-wall-head-front_91cfd9a5-4853-4573-9a08-1d4b521f6162.png?v=1788874747"},{"product_id":"ng-blu-multi-zone-12k-wall-mount-air-handler","title":"NG BLU+ Multi-Zone 12,000 BTU Wall-Mount Air Handler - 23.1 SEER2 (MIBMHW12D)","description":"\u003cp\u003eA one-ton head in the same compact 31.57 in. chassis as the 9K, so it fits the same wall opening and the same line set sizes while adding a third more capacity and nearly double the moisture removal at 1.3 L\/h. That dehumidification figure is the reason to choose the 12K over the 9K in a humid climate even when the sensible load is borderline. Down to 20 dB(A) on low fan. Requires a BLU+ multi-zone condenser.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU\/h (2,600 - 13,700 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal heating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU\/h (4,100 - 14,400 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23.1 \/ 12.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 (Region IV \/ Region V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11.5 \/ 8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 17°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,900 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -4°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6,700 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -13°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5,300 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMoisture removal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 L\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e382.6 \/ 294.3 \/ 194.2 \/ 153.0 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e46 \/ 43 \/ 37 \/ 20 \/ 19 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230V \/ 60Hz \/ 1Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan motor RLA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMetering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEXV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in. liquid, 3\/8 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax line length \/ height difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 ft \/ 49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.57 x 7.87 x 11.61 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.96 \/ 24.25 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor operating range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 - 90°F cooling, 32 - 86°F heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eMulti-zone component, sold separately\u003c\/h3\u003e\u003cp\u003eThis is an indoor component of a BLU+ multi-zone system and does not operate on its own. It must be paired with a BLU+ multi-zone condenser (MOBMH180D, MOBMH270D, MOBMH360D or MOBMH480D). Confirm total connected capacity and port sizing against the condenser before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804164382829,"sku":"MIBMHW12D","price":515.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-wall-head-front_6b817da9-300d-439a-aaa9-657fe65ab0ca.png?v=1788874753"},{"product_id":"ng-blu-multi-zone-18k-wall-mount-air-handler","title":"NG BLU+ Multi-Zone 18,000 BTU Wall-Mount Air Handler - 24.0 SEER2 (MIBMHW18D)","description":"\u003cp\u003eA one-and-a-half ton head for the largest zone on a multi-zone system, typically the main living area. Airflow nearly doubles over the 12K at 759 CFM on Turbo, and the gas line steps up to 1\/2 in., so it must land on a 1\/2 in. port at the condenser. Note the cabinet grows to 42.60 in. wide and 13.27 in. tall, which matters when planning wall space above a window or door header. Requires a BLU+ multi-zone condenser.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18,000 BTU\/h (3,600 - 20,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal heating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18,000 BTU\/h (7,600 - 22,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24.0 \/ 13.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 (Region IV \/ Region V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11.1 \/ 8.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.81\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 17°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -4°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,700 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -13°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7,900 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMoisture removal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4 L\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e759.3 \/ 500.3 \/ 441.4 \/ 370.8 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54 \/ 45 \/ 40.0 \/ 26 \/ 20 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230V \/ 60Hz \/ 1Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan motor RLA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMetering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEXV plus throttle valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in. liquid, 1\/2 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax line length \/ height difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98.4 ft \/ 65.6 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.60 x 9.21 x 13.27 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.42 \/ 39.68 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor operating range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 - 90°F cooling, 32 - 86°F heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eMulti-zone component, sold separately\u003c\/h3\u003e\u003cp\u003eThis is an indoor component of a BLU+ multi-zone system and does not operate on its own. It must be paired with a BLU+ multi-zone condenser (MOBMH180D, MOBMH270D, MOBMH360D or MOBMH480D). Confirm total connected capacity and port sizing against the condenser before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804164579437,"sku":"MIBMHW18D","price":652.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-wall-head-front_8edba7d0-3c33-4a49-a365-fc3f6d81bb50.png?v=1788874760"},{"product_id":"ng-blu-multi-zone-24k-wall-mount-air-handler","title":"NG BLU+ Multi-Zone 24,000 BTU Wall-Mount Air Handler - 23.5 SEER2 (MIBMHW24D)","description":"\u003cp\u003eThe largest wall-mounted head in the multi-zone range at two tons, with 2.7 L\/h of moisture removal, the most of any BLU+ indoor unit. Before specifying it, check the port sizing on your condenser: this head uses a 3\/8 in. liquid and 5\/8 in. gas connection, which is larger than every other multi-zone head in the line and larger than the standard multi-zone port. Confirm compatibility and any required adapters with NG before ordering.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,000 BTU\/h (9,700 - 27,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal heating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25,000 BTU\/h (11,300 - 32,700 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23.5 \/ 13.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 (Region IV \/ Region V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.0 \/ 7.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.08\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 17°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21,300 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17,800 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -4°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,300 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -13°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMoisture removal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.7 L\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e759.3 \/ 588.6 \/ 459.1 \/ 382.6 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54.0 \/ 48.5 \/ 43.5 \/ 27.5 \/ 20.5 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230V \/ 60Hz \/ 1Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan motor RLA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMetering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEXV plus throttle valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8 in. liquid, 5\/8 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax line length \/ height difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e164 ft \/ 82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.60 x 9.21 x 13.27 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.86 \/ 40.56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor operating range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 - 90°F cooling, 32 - 86°F heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eMulti-zone component, sold separately\u003c\/h3\u003e\u003cp\u003eThis is an indoor component of a BLU+ multi-zone system and does not operate on its own. It must be paired with a BLU+ multi-zone condenser (MOBMH180D, MOBMH270D, MOBMH360D or MOBMH480D). Confirm total connected capacity and port sizing against the condenser before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804164841581,"sku":"MIBMHW24D","price":748.12,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-wall-head-front_cbb0894c-cc9f-4338-a721-b3043eb05775.png?v=1788874767"},{"product_id":"ng-blu-multi-zone-9k-cassette-air-handler","title":"NG BLU+ Multi-Zone 9,000 BTU 4-Way Ceiling Cassette - 21.6 SEER2 (MIBMHC90D)","description":"\u003cp\u003eA four-way ceiling cassette for zones where a wall head would be visually intrusive or where wall space simply is not available: conference rooms, retail floors, open kitchens, finished basements with a dropped ceiling. Four-way discharge distributes air more evenly across a square room than a single-direction wall head, and the 9.65 in. body height fits standard T-bar ceiling plenums. The COP of 4.00 is the highest in the BLU+ indoor range. The decorative panel (PAMIC918D) is ordered separately.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000 BTU\/h (3,700 - 12,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal heating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.6 \/ 14.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 (Region IV \/ Region V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11.3 \/ 8.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 17°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,300 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8,300 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -4°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6,100 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -13°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4,900 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow (Turbo\/Hi\/Mi\/Lo\/Silent)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e417.9 \/ 364.9 \/ 306.1 \/ 194.2 \/ 147.2 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.5 \/ 40 \/ 37.0 \/ 26.0 \/ 24.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230V \/ 60Hz \/ 1Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor MCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.00A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan motor RLA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMetering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEXV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in. liquid, 3\/8 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax line length \/ height difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 ft \/ 49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBody dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.44 x 22.44 x 9.65 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35.27 \/ 41.89 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor operating range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 - 90°F cooling, 32 - 86°F heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eMulti-zone component, sold separately\u003c\/h3\u003e\u003cp\u003eThis is an indoor component of a BLU+ multi-zone system and does not operate on its own. It must be paired with a BLU+ multi-zone condenser (MOBMH180D, MOBMH270D, MOBMH360D or MOBMH480D). Confirm total connected capacity and port sizing against the condenser before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804165136493,"sku":"MIBMHC90D","price":606.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-ceiling-cassette-4-way_d1938ae1-78ae-4b4b-9f5a-51bddfc5c4da.png?v=1788874778"},{"product_id":"ng-blu-multi-zone-12k-cassette-air-handler","title":"NG BLU+ Multi-Zone 12,000 BTU 4-Way Ceiling Cassette - 21.1 SEER2 (MIBMHC12D)","description":"\u003cp\u003eThe one-ton cassette, same body and same 22.44 in. square footprint as the 9K, so ceiling framing and panel selection do not change between the two. Airflow is identical; the extra capacity comes from the coil and the EXV metering rather than the fan, which keeps it within the same acoustic envelope. This is usually the right size for a 400 to 550 square foot commercial bay or a large open room. Decorative panel PAMIC918D sold separately.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU\/h (3,700 - 14,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal heating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.1 \/ 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 (Region IV \/ Region V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.4 \/ 7.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 17°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,300 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -4°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6,700 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -13°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5,300 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow (Turbo\/Hi\/Mi\/Lo\/Silent)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e417.9 \/ 364.9 \/ 306.1 \/ 194.2 \/ 147.2 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e46 \/ 42.0 \/ 38.5 \/ 26.5 \/ 24.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230V \/ 60Hz \/ 1Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor MCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.00A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan motor RLA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMetering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEXV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in. liquid, 3\/8 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax line length \/ height difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 ft \/ 49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBody dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.44 x 22.44 x 9.65 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35.27 \/ 41.89 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor operating range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 - 90°F cooling, 32 - 86°F heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eMulti-zone component, sold separately\u003c\/h3\u003e\u003cp\u003eThis is an indoor component of a BLU+ multi-zone system and does not operate on its own. It must be paired with a BLU+ multi-zone condenser (MOBMH180D, MOBMH270D, MOBMH360D or MOBMH480D). Confirm total connected capacity and port sizing against the condenser before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804165496941,"sku":"MIBMHC12D","price":638.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-ceiling-cassette-4-way_11944348-8864-4dce-920c-01105f411b7b.png?v=1788874785"},{"product_id":"ng-blu-multi-zone-18k-cassette-air-handler","title":"NG BLU+ Multi-Zone 16,800 BTU 4-Way Ceiling Cassette - 20.7 SEER2 (MIBMHC18D)","description":"\u003cp\u003eThe largest BLU+ cassette. Worth reading the rating carefully: it is catalogued as an 18K but the published cooling capacity is 16,800 BTU\/h, with heating at the full 18,000 BTU\/h. Cold-weather output is strong for a cassette, holding 14,800 BTU\/h at 17°F. The gas connection is 1\/2 in., so it needs a large port on the condenser. Body dimensions match the 9K and 12K cassettes and it uses the same PAMIC918D panel, sold separately.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16,800 BTU\/h (5,300 - 17,800 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal heating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.7 \/ 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 (Region IV \/ Region V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11.4 \/ 8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 17°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14,800 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,800 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -4°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -13°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8,300 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow (Turbo\/Hi\/Mi\/Lo\/Silent)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e447.3 \/ 388.5 \/ 317.8 \/ 194.2 \/ 147.2 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48 \/ 44.0 \/ 41.0 \/ 28.5 \/ 24.5 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230V \/ 60Hz \/ 1Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor MCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.00A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan motor RLA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMetering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEXV plus throttle valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in. liquid, 1\/2 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax line length \/ height difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98.4 ft \/ 65.6 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBody dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.44 x 22.44 x 9.65 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35.27 \/ 41.89 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor operating range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 - 90°F cooling, 32 - 86°F heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eMulti-zone component, sold separately\u003c\/h3\u003e\u003cp\u003eThis is an indoor component of a BLU+ multi-zone system and does not operate on its own. It must be paired with a BLU+ multi-zone condenser (MOBMH180D, MOBMH270D, MOBMH360D or MOBMH480D). Confirm total connected capacity and port sizing against the condenser before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804165759085,"sku":"MIBMHC18D","price":669.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-ceiling-cassette-4-way_16b71d7f-5353-401c-96e0-bb86fccf5ff3.png?v=1788874792"},{"product_id":"ng-blu-cassette-decorative-panel-9k-18k","title":"NG BLU+ Decorative Ceiling Panel for 9K-18K 4-Way Cassettes (PAMIC918D)","description":"\u003cp\u003eThe finished grille that closes off a BLU+ four-way cassette at the ceiling line. It carries the supply louvers, the central return grille and the filter, and one is required for every cassette installed. Cassette bodies ship without a panel so that installers can order the correct trim on jobs where ceiling type or panel finish is decided late. This panel covers the 9K, 12K and 18K cassette bodies, which share a common chassis.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMIBMHC90D, MIBMHC12D, MIBMHC18D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-way discharge decorative grille panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeparately from the cassette body; one required per cassette\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eMulti-zone component, sold separately\u003c\/h3\u003e\u003cp\u003eThis is an indoor component of a BLU+ multi-zone system and does not operate on its own. It must be paired with a BLU+ multi-zone condenser (MOBMH180D, MOBMH270D, MOBMH360D or MOBMH480D). Confirm total connected capacity and port sizing against the condenser before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804166053997,"sku":"PAMIC918D","price":120.04,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-ceiling-cassette-4-way_ad9d3b50-cd16-4439-b25e-ec1f1b800df5.png?v=1788874798"},{"product_id":"ng-ez-central-24k-ducted-heat-pump-system","title":"NG EZ Central 24,000 BTU Ducted Inverter Heat Pump System - R-454B (EZCO24K2 \/ EZCI24K2)","description":"\u003cp\u003eA two-ton ducted inverter heat pump: a multi-position air handler matched to a variable-speed condenser, for homes that already have duct work and do not want ductless heads on the walls. Inverter-driven ducted systems hold tighter temperature and pull more moisture out of the air than a single-stage system of the same nominal tonnage, because they spend most of their run time at partial load rather than cycling. Uses R-454B, the low-GWP A2L refrigerant replacing R-410A.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEZCI24K2 (multi-position air handler)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEZCO24K2 (inverter condenser)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-454B (A2L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMatched ducted split system, cooling and heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eAbout the EZ Central Series\u003c\/h3\u003e\u003cp\u003eEZ Central is NG's ducted platform: a multi-position variable-speed air handler matched to an inverter condenser, communicating over a 2-wire AWG 20 bus. It is the right choice where duct work already exists and the customer does not want indoor heads. All models use R-454B and are ETL listed to UL 1995 and CSA C22.2 No. 236.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804166316141,"sku":"EZCO24K2\/EZCI24K2","price":2771.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-ez-central-system-bundle_fb405bf1-522e-4503-b802-ce2ca6b137b8.png?v=1788874807"},{"product_id":"ng-ez-central-36k-ducted-heat-pump-system","title":"NG EZ Central 36,000 BTU Ducted Inverter Heat Pump System - 16.1 SEER2, R-454B (EZCO36K2 \/ EZCI36K2)","description":"\u003cp\u003eA three-ton matched ducted heat pump for a whole-house replacement on existing duct work. The number worth noticing is the heating side: 30,000 BTU\/h at 17°F and 20,000 BTU\/h at -13°F, which for many northern homes means the heat pump carries most of the winter load rather than handing off to strip heat. The air handler is a 21 in. square, 49 in. tall multi-position cabinet that fits an ordinary closet or basement footprint, and it accepts either 115V or 208\/230V line power. At 16.1 SEER2 the efficiency is solidly mid-range rather than premium; the trade is cold-weather capacity and a lower installed cost than a ductless multi-zone of the same tonnage.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEZCI36K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEZCO36K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36,000 BTU\/h (8,300 - 38,900 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal heating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36,000 BTU\/h (6,700 - 41,300 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16.1 \/ 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 (Region IV \/ Region V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.7 \/ 7.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating H32 rated \/ COP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25,600 BTU\/h \/ 2.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating H42 rated \/ COP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27,000 BTU\/h \/ 2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 17°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -4°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -13°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling at 109°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor power supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115 \/ 208 \/ 230V, 60Hz, 1Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor power supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 60Hz, 1Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,600W \/ 15.2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,100W \/ 13.1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor MCA (115V \/ 208-230V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.0A \/ 6.0A; max fuse 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor MCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24A \/ 30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAWG 20-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-454B (A2L), 116.40 oz factory charge; 0.7 oz\/ft additional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8 in. liquid, 3\/4 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax line length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e246 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor airflow (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,188.97 \/ 1,083.02 \/ 971.19 \/ 865.24 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,413.2 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor sound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGMCC rotary, 10,010W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.02 x 21.02 x 49.02 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.24 x 16.14 x 31.89 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight (indoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e129.41 \/ 153.88 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight (outdoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e153.22 \/ 163.58 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13 - 122°F cooling, -13 - 75°F heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eAbout the EZ Central Series\u003c\/h3\u003e\u003cp\u003eEZ Central is NG's ducted platform: a multi-position variable-speed air handler matched to an inverter condenser, communicating over a 2-wire AWG 20 bus. It is the right choice where duct work already exists and the customer does not want indoor heads. All models use R-454B and are ETL listed to UL 1995 and CSA C22.2 No. 236.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804166742125,"sku":"EZCO36K2\/EZCI36K2","price":3479.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-ez-central-system-bundle_fd75dcab-3251-4b2b-bd43-d9924a47678d.png?v=1788874816"},{"product_id":"ng-ez-central-48k-ducted-heat-pump-system","title":"NG EZ Central 48,000 BTU Ducted Inverter Heat Pump System - 16 SEER2, R-454B (EZCO48K2 \/ EZCI48K2)","description":"\u003cp\u003eA four-ton ducted inverter system with the best cold-weather retention in the EZ Central range: 39,000 BTU\/h at 17°F, which is above the nominal-to-17°F ratio of either the 36K or the 60K, and 32,500 BTU\/h still available at -13°F. Airflow tops out near 1,600 CFM, so the existing duct system needs to be checked for static pressure before it goes in; undersized returns are the usual reason a system this size underperforms. Larger 52.99 in. air handler cabinet and a 40A outdoor circuit.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEZCI48K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEZCO48K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (16,600 - 49,900 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal heating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (15,300 - 49,500 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 \/ 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 (Region IV \/ Region V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.5 \/ 7.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating H32 rated \/ COP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32,400 BTU\/h \/ 2.47\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating H42 rated \/ COP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38,000 BTU\/h \/ 1.85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 17°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e39,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -4°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -13°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling at 109°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor power supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115 \/ 208 \/ 230V, 60Hz, 1Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor power supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 60Hz, 1Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4,800W \/ 22.2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4,085W \/ 18.3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor MCA (115V \/ 208-230V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.5A \/ 11.0A; max fuse 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor MCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAWG 20-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-454B (A2L), 134.04 oz factory charge; 0.7 oz\/ft additional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8 in. liquid, 3\/4 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax line length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e246 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor airflow (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,600.99 \/ 1,471.50 \/ 1,283.15 \/ 1,094.80 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,037.1 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor sound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHighly rotary, 16,250W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.02 x 24.49 x 52.99 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38.58 x 16.34 x 38.39 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight (indoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e162.92 \/ 190.92 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight (outdoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e192.90 \/ 224.21 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13 - 122°F cooling, -13 - 75°F heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eAbout the EZ Central Series\u003c\/h3\u003e\u003cp\u003eEZ Central is NG's ducted platform: a multi-position variable-speed air handler matched to an inverter condenser, communicating over a 2-wire AWG 20 bus. It is the right choice where duct work already exists and the customer does not want indoor heads. All models use R-454B and are ETL listed to UL 1995 and CSA C22.2 No. 236.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804167102573,"sku":"EZCO48K2\/EZCI48K2","price":4646.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-ez-central-system-bundle_c47612a9-d4b4-44c1-849c-a8834aa3d357.png?v=1788874823"},{"product_id":"ng-ez-central-60k-ducted-heat-pump-system","title":"NG EZ Central 60,000 BTU Ducted Inverter Heat Pump System - 15.2 SEER2, R-454B (EZCO60K2 \/ EZCI60K2)","description":"\u003cp\u003eThe largest EZ Central system, catalogued as a 60K. Read the capacity line carefully before quoting it: the manufacturer's specification sheet rates this model at 54,000 BTU\/h cooling and heating, not 60,000, with a maximum of 55,000 BTU\/h at the top of the inverter range. Size the job to the 54,000 figure. It moves up to 1,807 CFM at full airflow, which demands a duct system designed for it, and draws 27.4A in cooling on a 40A circuit. Suited to large homes and light commercial spaces with existing duct work.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEZCI60K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEZCO60K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54,000 BTU\/h (21,000 - 55,000 BTU\/h) - see note below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated heating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54,000 BTU\/h (26,000 - 55,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.2 \/ 8.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 (Region IV \/ Region V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.4 \/ 6.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating H32 rated \/ COP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h \/ 2.34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating H42 rated \/ COP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38,000 BTU\/h \/ 1.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 17°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -4°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -13°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling at 109°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41,800 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e58,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor power supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115 \/ 208 \/ 230V, 60Hz, 1Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor power supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 60Hz, 1Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6,200W \/ 27.4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4,650W \/ 21A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor MCA (115V \/ 208-230V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.5A \/ 11.0A; max fuse 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor MCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e39A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAWG 20-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-454B (A2L), 134.04 oz factory charge; 0.7 oz\/ft additional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8 in. liquid, 3\/4 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax line length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e246 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor airflow (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,807.00 \/ 1,583.33 \/ 1,359.67 \/ 1,136.00 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,037.1 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor sound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHighly rotary, 16,250W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.02 x 24.49 x 52.99 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38.58 x 16.34 x 38.39 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight (indoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e162.92 \/ 190.92 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight (outdoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e192.90 \/ 224.21 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13 - 122°F cooling, -13 - 75°F heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eAbout the EZ Central Series\u003c\/h3\u003e\u003cp\u003eEZ Central is NG's ducted platform: a multi-position variable-speed air handler matched to an inverter condenser, communicating over a 2-wire AWG 20 bus. It is the right choice where duct work already exists and the customer does not want indoor heads. All models use R-454B and are ETL listed to UL 1995 and CSA C22.2 No. 236.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804167463021,"sku":"EZCO60K2\/EZCI60K2","price":4787.37,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-ez-central-system-bundle_c7122ce7-b60f-404b-9123-df4639316dcd.png?v=1788874829"},{"product_id":"ng-saja-12k-115v-single-zone-heat-pump-r32","title":"NG SAJA 12,000 BTU Single-Zone Mini Split Heat Pump - 22 SEER2, 115V, R-32 (OSA32120 \/ ISA32120)","description":"\u003cp\u003eThe SAJA series is NG's R-32 platform, sitting below the R-454B BLU+ lines on price while still hitting strong efficiency numbers. This 115V system is the highest-rated model in the SAJA single-zone family at 22 SEER2, and it plugs into an ordinary 115V circuit, which makes it a common choice for garages, sunrooms, workshops and additions. AHRI certified and ETL listed to UL 1995 \/ CSA C22.2 No. 236. WiFi control is built in. One thing to plan for: the indoor fan motor is AC rather than DC on this model, so low-speed operation is slightly less refined than on the 220V versions.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISA32120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOSA32120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11,990 BTU\/h (3,516W); 12,000 BTU\/h at full stage, 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated heating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11,990 BTU\/h (3,516W); 12,300 BTU\/h at full stage, 47°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 cooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 heating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated power consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,040W cooling \/ 1,040W heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated running current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.1A cooling \/ 9.2A heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax input power \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,600W \/ 11A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115V~ \/ 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-32 (A2L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax discharge \/ suction pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.3 MPa \/ 2.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e353 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42 dB(A) indoor, 53 dB(A) outdoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor fan motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor fan motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGMCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in. liquid, 3\/8 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29.96 x 11.61 x 7.87 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.76 x 10.98 x 20.87 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.64 lb indoor \/ 50.71 lb outdoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWiFi, auto-restart, turbo mode, sleep mode, LCD display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eAbout the SAJA Series\u003c\/h3\u003e\u003cp\u003eSAJA is NG's R-32 platform. R-32 is a single-component A2L refrigerant with a GWP of 675, roughly a third that of R-410A, and it is easier to recover and recharge than a blend because it does not fractionate. AHRI certified, ETL listed to UL 1995 and CSA C22.2 No. 236, with WiFi, auto-restart, turbo mode, sleep mode and an LCD remote as standard.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804168773741,"sku":"OSA32120\/ISA32120","price":845.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-saja-system-head-condenser-remote_0fd024fb-b0d2-4c39-8fc1-479463688413.png?v=1788874845"},{"product_id":"ng-saja-12k-230v-single-zone-heat-pump-r32","title":"NG SAJA 12,000 BTU Single-Zone Mini Split Heat Pump - 21 SEER2, 208\/230V, R-32 (OSA32121 \/ ISA32121)","description":"\u003cp\u003eThe 240V SAJA 12K trades a point of SEER2 against the 115V model for a better heating rating (HSPF2 10 versus 9), a DC indoor fan motor, and half the running current at 4.2A. It is also the quietest unit in the SAJA single-zone range at 41 dB(A) indoors and 52 dB(A) outdoors. For any job where a 240V circuit exists, this is the better of the two 12K options. AHRI certified, ETL listed, WiFi enabled.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISA32121\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOSA32121\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11,935 BTU\/h (3,500W); 12,000 BTU\/h at full stage, 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated heating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,276 BTU\/h (3,600W); 12,300 BTU\/h at full stage, 47°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 cooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 heating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated power consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e920W cooling \/ 940W heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated running current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.2A cooling \/ 4.3A heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax input power \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,600W \/ 8A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V~ \/ 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-32 (A2L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax discharge \/ suction pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.3 MPa \/ 2.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e353 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41 dB(A) indoor, 52 dB(A) outdoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor fan motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor fan motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGMCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in. liquid, 3\/8 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29.96 x 11.61 x 7.87 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.76 x 10.98 x 20.87 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.64 lb indoor \/ 52.91 lb outdoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWiFi, auto-restart, turbo mode, sleep mode, LCD display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eAbout the SAJA Series\u003c\/h3\u003e\u003cp\u003eSAJA is NG's R-32 platform. R-32 is a single-component A2L refrigerant with a GWP of 675, roughly a third that of R-410A, and it is easier to recover and recharge than a blend because it does not fractionate. AHRI certified, ETL listed to UL 1995 and CSA C22.2 No. 236, with WiFi, auto-restart, turbo mode, sleep mode and an LCD remote as standard.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804173787245,"sku":"OSA32121\/ISA32121","price":845.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-saja-system-head-condenser-remote_fd524da5-e5e2-43a9-a117-0c96129d415c.png?v=1788874853"},{"product_id":"ng-saja-18k-230v-single-zone-heat-pump-r32","title":"NG SAJA 18,000 BTU Single-Zone Mini Split Heat Pump - 21 SEER2, 208\/230V, R-32 (OSA32181 \/ ISA32181)","description":"\u003cp\u003eA one-and-a-half ton R-32 system at 21 SEER2, sized for open living areas, large basements and small commercial suites. Cooling is rated 17,000 BTU\/h and heating slightly higher at 17,700 BTU\/h. DC fan motors on both the indoor and outdoor sections, 618 CFM of indoor airflow, and a 1\/2 in. gas line. AHRI certified and ETL listed, with WiFi control included rather than an add-on module.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISA32181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOSA32181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17,000 BTU\/h (4,982W), full stage at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated heating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17,700 BTU\/h (5,187W), full stage at 47°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 cooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 heating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated power consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,400W cooling \/ 1,440W heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated running current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.2A cooling \/ 6.3A heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax input power \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,200W \/ 12A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V~ \/ 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-32 (A2L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax discharge \/ suction pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.3 MPa \/ 2.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e618 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49 dB(A) indoor, 54 dB(A) outdoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor fan motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor fan motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGMCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in. liquid, 1\/2 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.80 x 12.44 x 8.74 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.91 x 11.81 x 21.85 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.35 lb indoor \/ 61.73 lb outdoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWiFi, auto-restart, turbo mode, sleep mode, LCD display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eAbout the SAJA Series\u003c\/h3\u003e\u003cp\u003eSAJA is NG's R-32 platform. R-32 is a single-component A2L refrigerant with a GWP of 675, roughly a third that of R-410A, and it is easier to recover and recharge than a blend because it does not fractionate. AHRI certified, ETL listed to UL 1995 and CSA C22.2 No. 236, with WiFi, auto-restart, turbo mode, sleep mode and an LCD remote as standard.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804176375917,"sku":"OSA32181\/ISA32181","price":1198.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-saja-system-head-condenser-remote_e9132b1e-e3fe-4725-a048-5cfa9e0edd37.png?v=1788874860"},{"product_id":"ng-saja-24k-230v-single-zone-heat-pump-r32","title":"NG SAJA 24,000 BTU Single-Zone Mini Split Heat Pump - 21 SEER2, 208\/230V, R-32 (OSA32241 \/ ISA32241)","description":"\u003cp\u003eTwo tons of R-32 inverter capacity from a single head at 21 SEER2, with 765 CFM of indoor airflow. Cooling and heating are rated identically at 24,000 BTU\/h full stage. The indoor unit is quieter than the 18K at 47 dB(A) despite moving more air, though the outdoor section is louder at 59 dB(A), which is worth considering for a condenser sitting under a bedroom window. Gas line steps up to 5\/8 in. AHRI certified, ETL listed, WiFi enabled.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISA32241\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOSA32241\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23,997 BTU\/h (7,033W); 24,000 BTU\/h at full stage, 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated heating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23,997 BTU\/h (7,033W); 24,000 BTU\/h at full stage, 47°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 cooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 heating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated power consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,000W cooling \/ 2,000W heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated running current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.7A cooling \/ 8.7A heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax input power \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,800W \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V~ \/ 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-32 (A2L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax discharge \/ suction pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.3 MPa \/ 2.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e765 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47 dB(A) indoor, 59 dB(A) outdoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor fan motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor fan motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGMCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in. liquid, 5\/8 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.87 x 12.91 x 8.94 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35.43 x 27.56 x 13.78 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.86 lb indoor \/ 94.79 lb outdoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWiFi, auto-restart, turbo mode, sleep mode, LCD display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eAbout the SAJA Series\u003c\/h3\u003e\u003cp\u003eSAJA is NG's R-32 platform. R-32 is a single-component A2L refrigerant with a GWP of 675, roughly a third that of R-410A, and it is easier to recover and recharge than a blend because it does not fractionate. AHRI certified, ETL listed to UL 1995 and CSA C22.2 No. 236, with WiFi, auto-restart, turbo mode, sleep mode and an LCD remote as standard.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804182241389,"sku":"OSA32241\/ISA32241","price":1587.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-saja-system-head-condenser-remote_773dd8e1-502b-427f-be74-f3b29af49dd8.png?v=1788874867"},{"product_id":"ng-saja-34k-single-zone-heat-pump-r32-50hz","title":"NG SAJA 34,000 BTU Single-Zone Mini Split Heat Pump - 17 SEER2, 220-240V 50Hz, R-32 (OSA32341 \/ ISA32341)","description":"\u003cp\u003eThe largest single-zone SAJA system, rated 34,000 BTU\/h in both cooling and heating with 941 CFM of indoor airflow. Two things to confirm before ordering. First, the power supply on the manufacturer's specification sheet is 220-240V at 50Hz, which is an international supply, not the 60Hz service used in North America; verify with NG whether a 60Hz version exists under this model number. Second, this unit is often catalogued as a 36K but the published rating is 34,000 BTU\/h. Efficiency is lower than the rest of the SAJA line at 17 SEER2 and HSPF2 8.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISA32341\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOSA32341\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33,964 BTU\/h (9,960W); 34,000 BTU\/h at full stage, 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated heating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33,964 BTU\/h (9,960W); 34,000 BTU\/h at full stage, 47°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 cooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 heating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated power consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,400W cooling \/ 3,000W heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated running current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15A cooling \/ 13A heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax input power \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,700W \/ 17A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220-240V~ \/ 50Hz - NOT a 60Hz North American supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-32 (A2L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax discharge \/ suction pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.3 MPa \/ 2.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e941 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52 dB(A) indoor, 58 dB(A) outdoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor fan motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor fan motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGMCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in. liquid, 5\/8 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.21 x 14.17 x 9.96 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35.43 x 27.56 x 13.78 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35.27 lb indoor \/ 101.41 lb outdoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWiFi, auto-restart, turbo mode, sleep mode, LCD display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eAbout the SAJA Series\u003c\/h3\u003e\u003cp\u003eSAJA is NG's R-32 platform. R-32 is a single-component A2L refrigerant with a GWP of 675, roughly a third that of R-410A, and it is easier to recover and recharge than a blend because it does not fractionate. AHRI certified, ETL listed to UL 1995 and CSA C22.2 No. 236, with WiFi, auto-restart, turbo mode, sleep mode and an LCD remote as standard.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804182863981,"sku":"OSA32341\/ISA32341","price":2147.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-saja-system-head-condenser-remote_9953c67a-b47e-43ac-900a-75bb112fc46a.png?v=1788874877"},{"product_id":"ng-saja-multi-zone-18k-condenser-2-zone-r32","title":"NG SAJA Multi-Zone 17,700 BTU Inverter Condenser - 2 Zone, 22 SEER2, R-32 (MOSA32181)","description":"\u003cp\u003eA two-zone R-32 condenser at 22 SEER2, and the least expensive way into a multi-zone system in the NG range. It pairs with any two SAJA indoor units in the published combinations, so a 7K bedroom head and a 12K living room head can run on their own schedules from one outdoor unit. Rated to -13°F ambient in heating, with 14,500 BTU\/h still available at 5°F. Comes pre-charged for 49.2 ft of line; longer runs need 0.16 oz per additional foot. Indoor units sold separately.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 drive 2 - up to 2 indoor units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity at 95°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17,700 BTU\/h (3,800 - 19,800 BTU\/h range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity at 47°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18,000 BTU\/h (4,200 - 22,000 BTU\/h range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 17°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14,700 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 \/ 12.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 (Region IV \/ Region V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 \/ 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 60Hz, 1Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling \/ heating power input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,440W \/ 1,390W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current (cooling \/ heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.39A \/ 6.17A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax input current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMCA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended fuse \/ MOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20A \/ 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.7 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGMCC rotary, 4,345W, 10-120 Hz, VG74 \/ 420ml oil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,529 CFM (2,600 m3\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound pressure \/ sound power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54 dB(A) \/ 64 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-32, 1.1 kg \/ 38.8 oz charged volume\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 g\/m (0.16 oz\/ft) beyond the 49.2 ft pre-charge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePort connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in. liquid, 3\/8 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax total pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e131 ft (40 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax length to one indoor unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 ft (25 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (IDU to ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49 ft (15 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference between IDUs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33 ft (10 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34.65 x 13.90 x 21.93 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75.0 \/ 80.5 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower wiring (ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 x 14 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterconnect wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 x 18 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13 - 125°F cooling, -13 - 75°F heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eValid indoor combinations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7+7, 7+9, 7+12, 7+18, 9+9, 9+12, 9+18, 12+12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eBuilding the system\u003c\/h3\u003e\u003cp\u003ePair with SAJA indoor units, ordered separately: 7K, 9K, 12K and 18K wall-mount heads (MISAW3207 \/ 3209 \/ 3212 \/ 3218) and the 12K 8-way cassette (MISAC3212). Permitted combinations are fixed by the manufacturer's chart, not by simple capacity addition.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804183257197,"sku":"MOSA32181","price":1412.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-saja-condenser-studio_7d25358c-9b6c-4701-921f-c6b5436e66ee.png?v=1788874884"},{"product_id":"ng-saja-multi-zone-30k-condenser-4-zone-r32","title":"NG SAJA Multi-Zone 30,000 BTU Inverter Condenser - 4 Zone, 23 SEER2, R-32 (MOSA32301)","description":"\u003cp\u003eA four-zone R-32 condenser at 23 SEER2, and the best low-temperature performer in the SAJA multi-zone range as a share of nameplate: 27,200 BTU\/h at 17°F against 30,000 BTU\/h nominal. It ships pre-charged for 98.4 ft of line and allows 263 ft total across the system, which covers most whole-house retrofits without field charging beyond the additional-length allowance. Two, three or four indoor units per the published combination chart. Indoor units sold separately.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 drive 4 - up to 4 indoor units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity at 95°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h (6,000 - 38,200 BTU\/h range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity at 47°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h (6,300 - 36,000 BTU\/h range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 17°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27,200 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 \/ 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 (Region IV \/ Region V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 \/ 8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 60Hz, 1Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling \/ heating power input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,400W \/ 2,250W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current (cooling \/ heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.65A \/ 9.98A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax input current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMCA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended fuse \/ MOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.6 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGMCC rotary, 7,640W, 12-120 Hz, VG74 \/ 620ml oil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,353 CFM (4,000 m3\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound pressure \/ sound power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e58 dB(A) \/ 68 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-32, 1.9 kg \/ 67.0 oz charged volume\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 g\/m (0.16 oz\/ft) beyond the 98.4 ft pre-charge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePort connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in. liquid, 3\/8 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax total pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e263 ft (80 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax length to one indoor unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115 ft (35 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (IDU to ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49 ft (15 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference between IDUs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33 ft (10 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41.18 x 17.91 x 31.81 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e148.8 \/ 157.6 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower wiring (ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 x 10 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterconnect wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 x 18 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13 - 125°F cooling, -13 - 75°F heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eValid indoor combinations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo, three or four heads; e.g. 9+18, 7+9+12, 9+9+12, 7+7+9+12, 9+9+12+12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eBuilding the system\u003c\/h3\u003e\u003cp\u003ePair with SAJA indoor units, ordered separately: 7K, 9K, 12K and 18K wall-mount heads (MISAW3207 \/ 3209 \/ 3212 \/ 3218) and the 12K 8-way cassette (MISAC3212). Permitted combinations are fixed by the manufacturer's chart, not by simple capacity addition.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804183683181,"sku":"MOSA32301","price":2307.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-saja-condenser-studio_c76b1297-c98b-4a71-b2c0-4d1b95fed30c.png?v=1788874890"},{"product_id":"ng-saja-multi-zone-36k-condenser-4-zone-r32","title":"NG SAJA Multi-Zone 36,000 BTU Inverter Condenser - 4 Zone, 23 SEER2, R-32 (MOSA32361)","description":"\u003cp\u003eThree tons of R-32 multi-zone capacity across up to four indoor units, with the highest COP in the SAJA range at 4.0 and heating capacity that reaches 43,000 BTU\/h at the top of the inverter range for fast recovery. Same cabinet as the 30K, so pad, clearances and mounting hardware are shared. The wider combination chart supports larger head pairings, up to 18+18 on two zones or four 12K heads. Indoor units sold separately.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 drive 4 - up to 4 indoor units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity at 95°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36,000 BTU\/h (6,350 - 38,500 BTU\/h range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity at 47°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36,000 BTU\/h (7,000 - 43,000 BTU\/h range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 17°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30,800 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 \/ 12.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 (Region IV \/ Region V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 \/ 7.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 60Hz, 1Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling \/ heating power input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,930W \/ 2,640W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current (cooling \/ heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.87A \/ 11.59A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax input current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMCA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended fuse \/ MOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30A \/ 45A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.9 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGMCC rotary, 7,640W, 12-120 Hz, VG74 \/ 620ml oil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,353 CFM (4,000 m3\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound pressure \/ sound power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e59 dB(A) \/ 69 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-32, 2.3 kg \/ 81.2 oz charged volume\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 g\/m (0.16 oz\/ft) beyond the 98.4 ft pre-charge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePort connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in. liquid, 3\/8 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax total pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e263 ft (80 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax length to one indoor unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115 ft (35 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (IDU to ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49 ft (15 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference between IDUs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33 ft (10 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41.18 x 17.91 x 31.81 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e154.3 \/ 163.1 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower wiring (ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 x 10 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterconnect wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 x 18 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13 - 125°F cooling, -13 - 75°F heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eValid indoor combinations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo, three or four heads, including 18+18, 12+18+18, 12+12+12+12, 9+9+18+18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eBuilding the system\u003c\/h3\u003e\u003cp\u003ePair with SAJA indoor units, ordered separately: 7K, 9K, 12K and 18K wall-mount heads (MISAW3207 \/ 3209 \/ 3212 \/ 3218) and the 12K 8-way cassette (MISAC3212). Permitted combinations are fixed by the manufacturer's chart, not by simple capacity addition.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804184109165,"sku":"MOSA32361","price":2863.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-saja-condenser-studio_4f5e681e-21de-4300-80d4-36600fed60bb.png?v=1788874896"},{"product_id":"ng-saja-multi-zone-7k-wall-mount-air-handler-r32","title":"NG SAJA Multi-Zone 7,000 BTU Wall-Mount Air Handler - WiFi, R-32 (MISAW3207)","description":"\u003cp\u003eThe smallest head in the SAJA multi-zone range, and the one to reach for when a load calculation comes in under about 8,000 BTU\/h: small bedrooms, home offices, nurseries. Undersizing rarely causes complaints in a ductless retrofit but oversizing does, because an oversized head satisfies the thermostat before it has run long enough to dehumidify. At 30 dB(A) on low it is quiet enough for a bedroom. Requires a SAJA multi-zone condenser; check the combination chart on the outdoor unit before finalizing a head schedule.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 60Hz, 1Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.13A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWeiling, 13W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan speed (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,280 \/ 1,130 \/ 1,015 \/ 900 r\/min cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow cooling (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e353 \/ 312 \/ 282 \/ 247 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow heating (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e353 \/ 324 \/ 288 \/ 247 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 \/ 38 \/ 35 \/ 30 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMoisture removal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\/h (1.5 lb\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePipe diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in. liquid, 3\/8 in. gas, 2\/3 in. drain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.02 x 7.80 x 11.50 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.60 \/ 22.00 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible outdoor units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMOSA32181, MOSA32301, MOSA32361\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eMulti-zone component, sold separately\u003c\/h3\u003e\u003cp\u003eThis indoor unit requires a SAJA multi-zone condenser (MOSA32181, MOSA32301 or MOSA32361) and does not operate on its own. NG publishes a combination chart for each condenser listing the permitted head groupings; check it before finalizing a schedule.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804186042477,"sku":"MISAW3207","price":294.31,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-saja-system-head-condenser-remote_0839c3a0-06e6-4096-ad9e-b2f45da8a4d5.png?v=1788874929"},{"product_id":"ng-saja-multi-zone-9k-wall-mount-air-handler-r32","title":"NG SAJA Multi-Zone 9,000 BTU Wall-Mount Air Handler - WiFi, R-32 (MISAW3209)","description":"\u003cp\u003eThe standard bedroom and office head for SAJA multi-zone systems at 9,000 BTU\/h in both cooling and heating. It shares the 7K's cabinet, airflow, fan motor and acoustics, so from an installation standpoint the two are interchangeable: same wall opening, same line set, same drain. The extra capacity comes from the coil. Suits rooms of roughly 300 to 450 square feet. Requires a SAJA multi-zone condenser.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 60Hz, 1Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.13A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWeiling, 13W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan speed (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,280 \/ 1,130 \/ 1,015 \/ 900 r\/min cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow cooling (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e353 \/ 312 \/ 282 \/ 247 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow heating (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e353 \/ 324 \/ 288 \/ 247 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 \/ 38 \/ 35 \/ 30 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMoisture removal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\/h (1.5 lb\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePipe diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in. liquid, 3\/8 in. gas, 2\/3 in. drain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.02 x 7.80 x 11.50 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.60 \/ 22.00 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible outdoor units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMOSA32181, MOSA32301, MOSA32361\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eMulti-zone component, sold separately\u003c\/h3\u003e\u003cp\u003eThis indoor unit requires a SAJA multi-zone condenser (MOSA32181, MOSA32301 or MOSA32361) and does not operate on its own. NG publishes a combination chart for each condenser listing the permitted head groupings; check it before finalizing a schedule.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804186533997,"sku":"MISAW3209","price":311.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-saja-system-head-condenser-remote_4cfc4a53-e842-4e1f-a8c8-552c47107377.png?v=1788874936"},{"product_id":"ng-saja-multi-zone-12k-wall-mount-air-handler-r32","title":"NG SAJA Multi-Zone 12,000 BTU Wall-Mount Air Handler - WiFi, R-32 (MISAW3212)","description":"\u003cp\u003eA one-ton head with meaningfully better dehumidification than the 9K at 1 kg\/h (2.2 lb\/h) of moisture removal, which is usually the deciding factor between the two in a humid climate. Heating is rated slightly above cooling at 12,300 BTU\/h. The cabinet grows to 34.49 in. wide, so check available wall width before substituting it for a 9K late in a job. Requires a SAJA multi-zone condenser.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,300 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 60Hz, 1Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.13A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWeiling, 13W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan speed (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,330 \/ 1,180 \/ 1,040 \/ 900 r\/min cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow cooling (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e382 \/ 324 \/ 294 \/ 235 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow heating (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e371 \/ 335 \/ 300 \/ 241 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42 \/ 40 \/ 36 \/ 32 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMoisture removal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kg\/h (2.2 lb\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePipe diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in. liquid, 3\/8 in. gas, 2\/3 in. drain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34.49 x 7.64 x 11.73 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.80 \/ 24.27 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible outdoor units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMOSA32181, MOSA32301, MOSA32361\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eMulti-zone component, sold separately\u003c\/h3\u003e\u003cp\u003eThis indoor unit requires a SAJA multi-zone condenser (MOSA32181, MOSA32301 or MOSA32361) and does not operate on its own. NG publishes a combination chart for each condenser listing the permitted head groupings; check it before finalizing a schedule.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804186828909,"sku":"MISAW3212","price":348.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-saja-system-head-condenser-remote_45cb92d6-3468-42c0-8d7f-3b166ed59e70.png?v=1788874942"},{"product_id":"ng-saja-multi-zone-18k-wall-mount-air-handler-r32","title":"NG SAJA Multi-Zone 17,000 BTU Wall-Mount Air Handler - WiFi, R-32 (MISAW3218)","description":"\u003cp\u003eThe largest wall-mounted head in the SAJA multi-zone range, for the main living area on a multi-zone job. Airflow nearly doubles the 12K at 618 CFM on Turbo and moisture removal reaches 3.5 lb\/h. The fan motor steps up to 30W, and the noise floor rises with it, so 35 dB(A) on low rather than 30 or 32. On a two-zone MOSA32181 condenser it can only be paired per the published combination chart; confirm before ordering. Requires a SAJA multi-zone condenser.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17,700 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 60Hz, 1Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWeiling, 30W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan speed (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,330 \/ 1,180 \/ 1,050 \/ 900 r\/min cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow cooling (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e618 \/ 559 \/ 500 \/ 441 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow heating (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e588 \/ 529 \/ 471 \/ 441 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49 \/ 45 \/ 40 \/ 35 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMoisture removal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.6 kg\/h (3.5 lb\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePipe diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in. liquid, 3\/8 in. gas, 2\/3 in. drain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38.82 x 8.86 x 12.40 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26.45 \/ 32.26 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible outdoor units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMOSA32181, MOSA32301, MOSA32361\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eMulti-zone component, sold separately\u003c\/h3\u003e\u003cp\u003eThis indoor unit requires a SAJA multi-zone condenser (MOSA32181, MOSA32301 or MOSA32361) and does not operate on its own. NG publishes a combination chart for each condenser listing the permitted head groupings; check it before finalizing a schedule.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804187156589,"sku":"MISAW3218","price":389.92,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-saja-system-head-condenser-remote_a92f8779-7c64-4cff-bbf4-0fbb9582cb63.png?v=1788874949"},{"product_id":"ng-saja-multi-zone-12k-cassette-air-handler-r32","title":"NG SAJA Multi-Zone 12,000 BTU 8-Way Ceiling Cassette - WiFi, R-32 (MISAC3212)","description":"\u003cp\u003eAn eight-way ceiling cassette rather than the more common four-way, which spreads supply air around the full perimeter of the grille and reduces the cold-draft complaints you get when a four-way blows directly at a desk or a seating area. Body is 22.44 in. square with a 25.59 in. panel, and the whole assembly is only 10.24 in. deep, so it drops into a standard ceiling plenum. Panasonic fan motor, 40 dB(A) at high speed. Requires a SAJA multi-zone condenser.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 60Hz, 1Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanasonic, 30W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan speed (Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e720 \/ 610 \/ 530 r\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow (Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e412 \/ 365 \/ 312 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 \/ 36 \/ 33 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMoisture removal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kg\/h (2.2 lb\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePipe diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in. liquid, 3\/8 in. gas, 25 mm (0.984 in.) drain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBody dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.44 x 22.44 x 10.24 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePanel dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.59 x 25.59 x 2.17 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBody net \/ gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.9 \/ 37.5 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePanel net \/ gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.9 \/ 8.2 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60.8 - 89.6°F (16 - 32°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible outdoor units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMOSA32181, MOSA32301, MOSA32361\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eMulti-zone component, sold separately\u003c\/h3\u003e\u003cp\u003eThis indoor unit requires a SAJA multi-zone condenser (MOSA32181, MOSA32301 or MOSA32361) and does not operate on its own. NG publishes a combination chart for each condenser listing the permitted head groupings; check it before finalizing a schedule.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804187549805,"sku":"MISAC3212","price":626.12,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-ceiling-cassette-4-way_4ac081d8-7306-48d7-9fa6-8fd15b5486a2.png?v=1788874955"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/collections\/ng-logo.png?v=1791258394","url":"https:\/\/willardshvacsupply.com\/collections\/ng-trade-blu-hvac-products.oembed","provider":"Willard's HVAC Supply","version":"1.0","type":"link"}