{"product_id":"ng-blu-eco-36k-230v-single-zone-heat-pump","title":"NG BLU+ ECO 36,000 BTU Single-Zone Mini Split Heat Pump - 19.5 SEER2, 208\/230V (OBMH361B \/ IBMH361B)","description":"\u003cp\u003eThe largest single-zone system in the BLU+ ECO line, at three tons from one head. This is the only single-zone ECO model rated down to -13°F outdoor for heating rather than 5°F, so it is the one to specify in a cold climate. Heating modulation reaches 44,000 BTU\/h at the top of its range for fast recovery, and the 213 ft maximum line length is long enough to put the condenser well away from the occupied space. Plan on a 35A circuit and a two-person lift for the 160 lb outdoor section.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIBMH361B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOBMH361B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36,000 BTU\/h (6,600 - 36,800 BTU\/h inverter range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal heating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36,000 BTU\/h (11,400 - 44,000 BTU\/h inverter range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.5 \/ 9.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 (Region IV \/ Region V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.1 \/ 7.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 17°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling at 109°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25,700 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230V \/ 60Hz \/ 1Ph (187 - 253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,830W \/ 17.0A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,580W \/ 16.0A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor MCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor MCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33.0A \/ 35A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG, 4-conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-454B (A2L), 112.88 oz factory charge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32 oz per ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8 in. liquid, 5\/8 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax line length \/ height difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e213.2 ft \/ 98.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor airflow (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e871.1 \/ 676.9 \/ 447.3 \/ 329.6 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor sound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e57.0 \/ 51.0 \/ 45.0 \/ 33.5 \/ 27.5 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor sound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,235.3 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGMCC rotary, 8,095W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.57 x 11.14 x 14.25 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.24 x 16.14 x 31.89 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight (indoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43.43 \/ 56.88 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight (outdoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150.35 \/ 160.27 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor operating range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13 - 122°F cooling, -13 - 75°F heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eAbout the BLU+ ECO Series\u003c\/h3\u003e\u003cp\u003eBLU+ ECO systems ship as matched pairs, one indoor head and one outdoor condenser, pre-engineered to work together. They use R-454B, the low-GWP A2L refrigerant replacing R-410A under the AIM Act, and are ETL listed to UL 1995 and CSA C22.2 No. 236 and AHRI certified. WiFi control is built in.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45794213199981,"sku":"OBMH361B\/IBMH361B","price":2181.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-blu-system-head-condenser-remote_89da6f31-8e30-47a1-9b61-26bfab0d32dc.png?v=1788797795","url":"https:\/\/willardshvacsupply.com\/products\/ng-blu-eco-36k-230v-single-zone-heat-pump","provider":"Willard's HVAC Supply","version":"1.0","type":"link"}