{"product_id":"ng-ez-central-36k-ducted-heat-pump-system","title":"NG EZ Central 36,000 BTU Ducted Inverter Heat Pump System - 16.1 SEER2, R-454B (EZCO36K2 \/ EZCI36K2)","description":"\u003cp\u003eA three-ton matched ducted heat pump for a whole-house replacement on existing duct work. The number worth noticing is the heating side: 30,000 BTU\/h at 17°F and 20,000 BTU\/h at -13°F, which for many northern homes means the heat pump carries most of the winter load rather than handing off to strip heat. The air handler is a 21 in. square, 49 in. tall multi-position cabinet that fits an ordinary closet or basement footprint, and it accepts either 115V or 208\/230V line power. At 16.1 SEER2 the efficiency is solidly mid-range rather than premium; the trade is cold-weather capacity and a lower installed cost than a ductless multi-zone of the same tonnage.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEZCI36K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor unit model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEZCO36K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal cooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36,000 BTU\/h (8,300 - 38,900 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal heating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36,000 BTU\/h (6,700 - 41,300 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16.1 \/ 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 (Region IV \/ Region V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.7 \/ 7.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating H32 rated \/ COP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25,600 BTU\/h \/ 2.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating H42 rated \/ COP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27,000 BTU\/h \/ 2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 17°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -4°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating at -13°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling at 109°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor power supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115 \/ 208 \/ 230V, 60Hz, 1Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor power supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 60Hz, 1Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,600W \/ 15.2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating input \/ current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,100W \/ 13.1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor MCA (115V \/ 208-230V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.0A \/ 6.0A; max fuse 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor MCA \/ max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24A \/ 30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAWG 20-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-454B (A2L), 116.40 oz factory charge; 0.7 oz\/ft additional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8 in. liquid, 3\/4 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax line length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e246 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor airflow (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,188.97 \/ 1,083.02 \/ 971.19 \/ 865.24 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,413.2 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor sound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGMCC rotary, 10,010W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.02 x 21.02 x 49.02 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.24 x 16.14 x 31.89 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight (indoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e129.41 \/ 153.88 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight (outdoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e153.22 \/ 163.58 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13 - 122°F cooling, -13 - 75°F heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eAbout the EZ Central Series\u003c\/h3\u003e\u003cp\u003eEZ Central is NG's ducted platform: a multi-position variable-speed air handler matched to an inverter condenser, communicating over a 2-wire AWG 20 bus. It is the right choice where duct work already exists and the customer does not want indoor heads. All models use R-454B and are ETL listed to UL 1995 and CSA C22.2 No. 236.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804166742125,"sku":"EZCO36K2\/EZCI36K2","price":3479.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-ez-central-system-bundle_fd75dcab-3251-4b2b-bd43-d9924a47678d.png?v=1788874816","url":"https:\/\/willardshvacsupply.com\/products\/ng-ez-central-36k-ducted-heat-pump-system","provider":"Willard's HVAC Supply","version":"1.0","type":"link"}