{"product_id":"ng-saja-multi-zone-18k-wall-mount-air-handler-r32","title":"NG SAJA Multi-Zone 17,000 BTU Wall-Mount Air Handler - WiFi, R-32 (MISAW3218)","description":"\u003cp\u003eThe largest wall-mounted head in the SAJA multi-zone range, for the main living area on a multi-zone job. Airflow nearly doubles the 12K at 618 CFM on Turbo and moisture removal reaches 3.5 lb\/h. The fan motor steps up to 30W, and the noise floor rises with it, so 35 dB(A) on low rather than 30 or 32. On a two-zone MOSA32181 condenser it can only be paired per the published combination chart; confirm before ordering. Requires a SAJA multi-zone condenser.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17,700 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 60Hz, 1Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWeiling, 30W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan speed (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,330 \/ 1,180 \/ 1,050 \/ 900 r\/min cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow cooling (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e618 \/ 559 \/ 500 \/ 441 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow heating (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e588 \/ 529 \/ 471 \/ 441 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49 \/ 45 \/ 40 \/ 35 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMoisture removal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.6 kg\/h (3.5 lb\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePipe diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in. liquid, 3\/8 in. gas, 2\/3 in. drain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38.82 x 8.86 x 12.40 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26.45 \/ 32.26 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible outdoor units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMOSA32181, MOSA32301, MOSA32361\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eMulti-zone component, sold separately\u003c\/h3\u003e\u003cp\u003eThis indoor unit requires a SAJA multi-zone condenser (MOSA32181, MOSA32301 or MOSA32361) and does not operate on its own. NG publishes a combination chart for each condenser listing the permitted head groupings; check it before finalizing a schedule.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804187156589,"sku":"MISAW3218","price":389.92,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-saja-system-head-condenser-remote_a92f8779-7c64-4cff-bbf4-0fbb9582cb63.png?v=1788874949","url":"https:\/\/willardshvacsupply.com\/products\/ng-saja-multi-zone-18k-wall-mount-air-handler-r32","provider":"Willard's HVAC Supply","version":"1.0","type":"link"}