{"product_id":"ng-saja-multi-zone-7k-wall-mount-air-handler-r32","title":"NG SAJA Multi-Zone 7,000 BTU Wall-Mount Air Handler - WiFi, R-32 (MISAW3207)","description":"\u003cp\u003eThe smallest head in the SAJA multi-zone range, and the one to reach for when a load calculation comes in under about 8,000 BTU\/h: small bedrooms, home offices, nurseries. Undersizing rarely causes complaints in a ductless retrofit but oversizing does, because an oversized head satisfies the thermostat before it has run long enough to dehumidify. At 30 dB(A) on low it is quiet enough for a bedroom. Requires a SAJA multi-zone condenser; check the combination chart on the outdoor unit before finalizing a head schedule.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 60Hz, 1Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.13A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWeiling, 13W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan speed (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,280 \/ 1,130 \/ 1,015 \/ 900 r\/min cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow cooling (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e353 \/ 312 \/ 282 \/ 247 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow heating (Turbo\/Hi\/Mi\/Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e353 \/ 324 \/ 288 \/ 247 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 \/ 38 \/ 35 \/ 30 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMoisture removal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\/h (1.5 lb\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePipe diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in. liquid, 3\/8 in. gas, 2\/3 in. drain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.02 x 7.80 x 11.50 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.60 \/ 22.00 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible outdoor units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMOSA32181, MOSA32301, MOSA32361\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eMulti-zone component, sold separately\u003c\/h3\u003e\u003cp\u003eThis indoor unit requires a SAJA multi-zone condenser (MOSA32181, MOSA32301 or MOSA32361) and does not operate on its own. NG publishes a combination chart for each condenser listing the permitted head groupings; check it before finalizing a schedule.\u003c\/p\u003e\u003ch3\u003eInstallation and compliance\u003c\/h3\u003e\u003cp\u003eR-454B and R-32 are A2L refrigerants, classified as mildly flammable. Installation, charging and service must be performed by a licensed HVAC contractor holding EPA Section 608 certification and trained on A2L handling. Local code may require leak detection, minimum room volume per pound of charge, or specific line set materials. Verify requirements before quoting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are taken from the manufacturer's published data sheet and are subject to change without notice. Confirm capacity, electrical requirements and refrigerant charge against the documentation shipped with the unit before installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"NG Trade","offers":[{"title":"Default Title","offer_id":45804186042477,"sku":"MISAW3207","price":294.31,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2419\/1853\/files\/ng-saja-system-head-condenser-remote_0839c3a0-06e6-4096-ad9e-b2f45da8a4d5.png?v=1788874929","url":"https:\/\/willardshvacsupply.com\/products\/ng-saja-multi-zone-7k-wall-mount-air-handler-r32","provider":"Willard's HVAC Supply","version":"1.0","type":"link"}